Guang Zhou Cheng Min Electronic Technology Co., Ltd. Company Logo Guang Zhou Cheng Min Electronic Technology Co., Ltd.
5 1

FX1008-4-2-l

Contact Now* Send an Inquiry to this supplier.
or
Start Order * Name your price

Browse by Category

Contact us

Guang Zhou Cheng Min Electronic Technology Co., Ltd.
[China]

Address
Tianhe District yuan cun two cross road Guangzhou City No. 8 Quan Feng Commercial Building Room 903 Guangzhou Guangdong
Phone
86-020-37038973
Contact name
HUI LONG LIU

Quick Information

  • Brand Name: YOKOGAWA
  • Place of Origin: Japan
  • Model Number : FX1008-4-2-l

Description

Paperless Recorder FX1008-4-2-L
Paperless Recorder FX1000: FX1002、FX1004、FX1006、FX1008、FX1010、FX1012
At YOKOGAWA, we are committed to the "quality first, customer first" principle in all areas of our business, including product design, research and development, and sales and services. The new FX1000 paperless recorder exceeds customer expectations for quality, high performance and capability- at a price that meets the needs of a cost-sensitive market.
Contact us:

Contactshuilong liu Phone86020-37038973 Fax86020-37038509
QQ: 1832098270 / 1532873690  
Nethttp://www.gzcm1718.com  Postalcode510655

Detail:

Monitor display

You can use the keys to switch to any of the operation screens. The operating states of memory sampling, alarms, key lock, computation, and other conditions are graphically displayed. Supports Chinese, English, German, French, and Japanese.

Trend dispalyTrend display Digital displayDigital display Overview displayOverview display
Displays measured data as waveforms. Displays each channel's scale value, industrial units, user messages, and other information. In addition to displaying measurements digitally, it displays channel/tag, industrial units, and alarm statuses. Displays measurements and alarm statuses on all channels.
Trend display (log scale)Trend display (log scale) Stacked bar graphStacked bar graph  
You can display log scales for degree of vacuum (pressure input), and record the data (option). You can display and record power consumption of each piece of electronic equipment; useful for energy saving and equipment maintenance as part of environmental protection programs (option).  

Bar graph, historical trend, and information displays (alarm summaries, message summaries, and reports) are also included.

Intuitive operator controls

DISP/ENTER and arrow keysThe DISP/ENTER and arrow keys provide display mode and setting menu navigation. Clearly labeled menu, function, and record start/stop keys handle all setting and control operations.

IE browser monitor screen

IE browser monitor screen






 

Multi-Channel Measurement and Recording

Universal input signal measurement

Universal input signal measurement

GENERAL SPECIFICATIONS

Construction

Mounting: Flush panel mounting (on a vertical plane)
Mounting may be inclined downward up to 30 degrees from a horizontal plane.
Allowable panel thickness: 2 to 26 mm
Front panel: Water- and dustproof: Complies with IEC529-IP65 (excluding side-by-side mounting)

Input

Number of inputs: FX1002: 2 channels, FX1004: 4 channels, FX1006: 6 channels,
FX1008: 8 channels, FX1010: 10 channels, FX1012: 12 channels
Measurement intervals: FX1002, DX1004: 125 ms, 250 ms
FX1006, FX1008, FX1010, FX1012: 1 s, 2 s, 5 s
Inputs: DCV (20, 60, 200 mV, 1, 2, 6, 20, 50 V, 1-5 V)
TC (R, S, B, K, E, J, T, N, W, L, U, WRe)
RTD (Pt100, JPt100)
DI (Contact input, TTL level)
DCA (with external shunt resistor attached)
Measurement/display accuracy: Standard operating conditions: Temperature: 23 ± 2°C
Humidity: 55% ± 10%RH
Power supply voltage: 90 to 132 or 180 to 250 VAC
Power supply frequency: 50/60 Hz ± 1%
Warm-up time: At least 30 minutes. Other ambient conditions such as vibration should not adversely affect the operation.
Input Range Measurement Accuracy Digital Display Max. Resolution
DCV 1-5 V ±(0.05% of rdg+3 digits) 1 mV
Thermocouple* K ±(0.15% of rdg + 0.7°C)
–200 to –100°C: ±(0.15% of rdg + 1°C)
0.1°C
RTD Pt100 ±(0.15% of rdg+0.3°C) 0.1°C 0.1°C

* Does not include the accuracy of reference junction compensation

Display

Display: 5.7-inch TFT color LCD (240 × 320 dots)
* A section of the LCD monitor may contain pixels that are always on or off. The brightness of the LCD may also not be uniform due to the characteristics of the LCD. This is not a malfunction.
Display groups: Number of groups: 10
Number of channels that can be assigned to each group: Up to 6
Display color: Channel: Select from 24 colors
Background: White or black (selectable)
Trend display: Layout: Vertical, horizontal, or wide
Bar graph display: Direction: Vertical or horizontal (selectable)
Digital display: Update rate: 1 sec
Overview display: Measuring values and alarm status of all channels
Information display: Alarm summary, message summary, memory summary, report, stacked bar graph, status, Modbus status
Modbus log display: Displays the login log, error log, communication log (/C2, /C3, and /C7), FTP log (/C7), Web log (/C7), e-mail log (/C7), SNTP log (/C7), and DHCP log (/C7)
Tag display: Number of displayable characters: Up to 16
Displayable characters: English, Japanese, and Chinese
Messages: Number of displayable characters: Up to 32 alphanumeric
Displayable characters: English, Japanese, and Chinese
Historical display function: Plays back data from internal memory or external memory media.
Back light saver function: LCD back light dims or turns OFF (user selectable) if no keys have been pressed for a specified period (1, 2, 5, 10, 30, or 60 min).

Data Saving Function

External storage medium: Medium: CompactFlash memory card (CF card) (on FXs with a CF card slot)
Internal memory: Medium: Flash memory
Format: FAT32 or FAT16
Capacity: 400 MB
Maximum number of files that can be saved: 400 (total number of display data and event data files)
Operation: FIFO (First In, First Out)

Alarm Function

Number of alarm levels: Up to four for each channel
Alarm types: High limit, low limit, differential high limit, difference low limit, high rate-of-change limit, low rate-of-change limit, alarm delay high limit, and alarm delay low limit

Event Action Function

General: A particular action can be executed by particular event.
Number of event actions: 40 actions can be set

Security Functions

General: Login function or key lock function can be set for each key operation or communication operation.
Key lock function: On/off and password can be set for each operation key and FUNC operation.
Login function: User name and password to login can be set.
System administrators: 5 (with access to all operations)
Users: 30 (with access to operations based on their user access rights)

Clock

Clock: With calendar function (Western calendar)
Accuracy: ±50 ppm (0 to 50°C); does not include the delay (1 second or less) that occurs when the power is turned on.

Batch Function

General: Data display and data management with batch name, text field function and batch comment function are available.

Power Supply

Rated power supply: 100 to 240 VAC (automatic switching)
Allowable power supply voltage range: 90 to 132 or 180 to 264 VAC
Rated power supply frequency: 50/60 Hz (automatic switching)
Power consumption: Max. 45 VA (for 240 VAC power supply)

NORMAL OPERATING CONDITIONS

Supply voltage: 90 to 132, 180 to 250 VAC
Rated power supply frequency: 50 Hz ±2%, 60 Hz ±2%
Ambient temperature: 0 to 50°C
Ambient humidity: 20 to 80% RH (at 5 to 40°C), 10 to 50% (at 40 to 50°C)


Product Image

  • FX1008-4-2-l image

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To HUI LONG LIU
Guang Zhou Cheng Min Electronic Technology Co., Ltd.